Other instruments

  • UT273 / UT275
  • UT273 / UT275
UT273 / UT275UT273 / UT275

UT273 / UT275

  • Product description: Clamp Earth Ground Testers
  • INQUIRY

Features

1. 10000 display count

2. 0.001Ω resolution

3. Auto range

4. Data hold

5. Resistance limit alarm

6. Auto calibration

7. Auto power off

8. LCD backlight


Specifications
Model UT273 UT275
Earth Ground Resistance (Ω) 0.01~0.099Ω ±(1%+0.01) ±(1%+0.01)
0.1~0.99Ω ±(1%+0.01) ±(1%+0.01)
1.0~49.9Ω ±(1.5%+0.1) ±(1.5%+0.1)
50.0~99.5Ω ±(2%+0.5) ±(2%+0.5)
100~199Ω ±(3%+1) ±(3%+1)
200~395Ω ±(10%+5) ±(10%+5)
400~590Ω ±(20%+10) ±(20%+10)
600~1000Ω ±(25%+20) ±(25%+20)
Leakage Current (A) 0.00~299mA ±(2.5%+2mA)
0.30~2.99A ±(2.5%+100mA)
3.00~30.0A ±(2.5%+300mA)
Features
Max Display 9999 9999
Auto Range
Jaw Capacity 28mm 28mm
Auto Power Off
Low Battery    Indication ≤5.2V
Data Hold
Data Storage 30 30
Data Recall
LCD Backlight
Auto Calibration
Resistance Limit Alarm
General Characteristics 
Power 1.5V Alkaline Batteries (LR6) ×4
LCD Size 47mm X 28.5mm     
Product Color Red and Grey       
Product Net Weight 1320g 
Product Size 293mm X 90mm X 66mm  
Standard Accessories Batteries, Test Ring, Tool Box
Standard Individual Packing Gift Box, English Manual
Standard Quantity Per Carton 5pcs
Standard Carton Measurement 510×375×320mm (0.06CBM Per Standard Carton)
Standard Carton Gross Weight 15.2kg